Engtips. China and Europe remain the most important electric vehicle ...

A restrained retaining wall with fixity between the footin

PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying.Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines. Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools.May 29, 2023 · Apartment Building Collapse46. "A six-story apartment complex partially collapsed Sunday evening in the city of Davenport, Iowa, authorities said. It was not immediately clear if there were any fatalities or how many people may be missing or trapped in the building. Davenport Mayor Mike Matsen said there were "several people unaccounted for ... A guide to the most eco-friendly and sustainable luxury hotels in England. The impact that travel has on the planet is causing concern for an increasing number of travelers. Althou... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home; Forums; Structural Engineers; Activities; Welding, Bonding & Fastener …We've been conditioned to tie rewards to travel. But by focusing on rewards beyond travel, we can expand our points and miles freedom. Increased Offer! Hilton No Annual Fee 70K + F...Here are tried and tested tips for a successful first family vacation to Europe. Update: Some offers mentioned below are no longer available. View the current offers here. My famil...LB.HESSEN-THÜRINGEN GZZINSDIFF.ANL.07C/19-07 V19(34) (DE000HLB33W0) - All master data, key figures and real-time diagram. The Landesbank Hessen-Thüringen Girozentrale-Bond has a ma... Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools. Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search.PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Happy Friday. Looking at replacing the entire bottom of a 60' diameter tank. Given the foundation configuration and some other challenges, the recommended solution is to install a second bottom over the existing bottom as specified in API 653 9.10.2. Looking for a couple bench marks from members. - Confirmation there isn't an API-653 standard ...Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines.I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ...Deflections under seismic loading - Part 2. It's my understanding that 4.1.8.11.3) d) v) allows us to use a larger period specifically to check seismic deflections. This means I'll have a different base shear than my regular elastic analysis, so I always run a distinct case anyways.Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Programmable logic controllers (PLC). Includes problem solving collaboration tools.The caustic scrubber is used to absorb the sour gases like H2S and CO2. To design this, you need to consider the system as an absorption column. For that you need to calculate how many equilibrium stages you have. Do not forget you have , at least, one chemical reaction (H2S + 2NaOH --> Na2S + 2H2O) if your stream doesn't have CO2.Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end …The nosing provides clearance space for your heel to drop on the tread. If there were no nosing, your heel might hit the riser and you will stumble forward (and probably fall if you are not holding n the handrail). msquared48 (Structural) 20 Apr 09 19:27. To encourage tripping as you go up the stairs.Engineering Reference. Free Engineering Books Pdf Is The Best Wanted Website For All Engineers. Download Free Engineering Books Online Which Related To All Engineering …It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …A common rule for situations like this is extend the depth of calculation to the point where the added pressure is 10% of existing pressure. the total extent of settlement is informed by soil modulus and the consolidation index (Cc) or consolidation ratio (Cec). If the clay is overconsolidated, then it'd be Cr, or Cer.Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …But, I expand on them a little: 1) Handbook of Steel Connection Design and Details by Akbar Tamboli. 2) The Following AISC design guidess: a) DG1: Base Plates. b) DGs 4 & 16 for bolted end plate moment connections. c) DGs 12 & 13 for retrofit of existing moment connections and stiffeners for moment …The caustic scrubber is used to absorb the sour gases like H2S and CO2. To design this, you need to consider the system as an absorption column. For that you need to calculate how many equilibrium stages you have. Do not forget you have , at least, one chemical reaction (H2S + 2NaOH --> Na2S + 2H2O) if your stream doesn't have CO2. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. RE: Required Bolt Area of standard flange. TGS4(Mechanical)1 Apr 06 17:26. You should also refer to ASME PCC-1. As far as the "required" bolt area goes, the B16.5 standard specifies bolt sizes to use, and, like codeeng says, you are allowed to design to the pressures/temperatures listed in B16.5, RE: Required Bolt Area of standard flange.LIVERPOOL, England (AP) — Liverpool was denied a last-minute penalty after fighting back to draw 1-1 with Manchester City on Sunday in the final Premier League …1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …1) Perforated. There are code restrictions on why you can use this. It is generally less expensive than the FTAO (Force Transfer Around Openings) method because it does not require you to use straps around all the openings. 2) FTAO: To me, this method is merely a "rational" method.Hi all, I'm designing a diesel tank 14m Diameter, 15m high tank with a fixed roof (rafters and roof plate). Max inlet flow rate = 870 m^3/h DN250 Max outlet flo Electric motors & generators engineering. (55332 members) forum237 - Professional forum and technical support for engineers for Electric motors & generators engineering. Includes problem solving collaboration tools. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. The kitchen in question is for a residential hall at a college. 2. bookowski (Structural) 17 Feb 13 21:18. Commentary for ASCE7 provides additional occupanies/situations. It lists "Kitchen, other than domestic = 150psf" with a note to use the actual equip. weight if greater. WWTEng (Structural)I attached a drawing just in case I can't explain myself clear enough. Anyway, I read that 'A relief valve is only needed if no other measures are provided to detect low flow conditions and shut down the centrifugal pump to prevent damage', well in my situation, there isn't a flow measuring instrument installed upstream of …Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …3 May 05 08:35. An estimate of Young's Modulus for concrete is 57,000 (f'c)^2. For cement grout mixes used in augercast piles (usually 3000 psi to 8000 psi), does anyone know of a similar equation to estimate the elasticity? Based on laboratory testing, elasticity of grout is not anywhere near the elasticity of same strength concrete mixes.Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search.Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like … Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools. Qatar has for months been criticized for mistreating migrant workers. Qatar, one of the world’s richest countries and the winner of the bid to host the soccer World Cup in 2022, ha...Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …7 Feb 16 11:02. I am designing a isolated footing in SAFE but I am confused that how to check the footing against uplift? Soil pressure are coming as mentioned below. Against dead load Max = -9.08 KN/m^2 and Min = -18 KN/m^2. Against wind load is Max = 53.83 KN/^m2 and Min = -38.74 Kn/m^2. footing is safe against uplift????Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ...Construction Process2. Construction Process. 2. As a new junior engineer without much construction experience, I wanted to ask whether there is a trustworthy resource which goes into a detailed narrative of the construction process, encompassing from the beginning paperwork, typical teams making up a project, …. My preferred method is to use 3 celas elemRE: Required Bolt Area of standard flange. TGS4(Mec Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Global Internet of People News: This is the News-site for the company Global Internet of People on Markets Insider Indices Commodities Currencies Stocks DASSAULT: CATIA products. (15414 members) forum5 Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. We calculate the rms value of fault current (If) at...

Continue Reading